Is it plug and play? Ive checked all my hoses for clogs and skimmer and pump baskets are clean. From the Hayward Ecostar Owners Manual: the Heat Sink Overheated error indicates that the heatsink on the bottom of the drive has overheated. The arrow should point in the same direction as the water flow. switch in the center. i know there is a low spead and hit speed switch when i take off the cover but it looks ok. it seems like the contacts get stuck together preventing the pump to turn on? Air leaks are another source of priming issues. Hi John, if the outlet is GFCI, check the TEST button, it may have tripped. Water into return is ok. Edith, low flow into the pump could be an air leak in front of the pump, usually a loose pump lid, missing pump lid o-ring, or a loose pipe coming into the pump. This noise does not happen when the water is flowing through the heater but it is not turned on. The cell amperage is above the maximum limit. The early revisions dont work with the TCELL5 or TCELL9. The 2 bolts connecting it to the platform just turn and turn and go nowhere. We live in Arizona, so the automatic freeze setting isnt an issue. 9,000 gallon in ground pool. None of the indicating lights are on. "headline": "Hayward Pool Pump Troubleshooting",
I opened the back and was spinning the rod and it eventually started. Attached please find a copy of the Aqua Plus Operation Manual Please note Section - Configuration Menu Items, Cell Type Selection, page 16. Now there is no water running from the pool to the motor basket. Hi Rodney, well the Green wire should be ground, so that eliminates one choice. However, when the filter is running for about 2-3 hours, the pressure increases to 20 psi, and the output water flow is minimal at best (extremely slow). i hope this helps, but I am also maybe missing something. If there is a little noise, check the motor capacitor, or look at the motor switches in the back, look for anything that looks or smells funny. 2. If the filter was a problem, you may notice higher than normal filter pressure (compared to the old pump). Motor wiring is pretty simple, green to ground and the other two wires, doesnt matter which one, go to terminals L1 and L2. One of them was arguably the best-constructed route from London [Marylebone] to Manchester. 3 things are key, 1. Hi Kathleen, sounds like a leak from the shaft seal, unless water is running out of the pump exit fitting, and running down the housing and dripping off the bottom. Hi, could be a lot of things, first I would use a test meter or outlet checker to be sure the outlet has power. We knows its not electrical. Motor rate state 4 as a max amps, I dont notice a strange noise and water is flowing normal when running, I dont have a check valve in front of pump so it takes 1 minute to get prime, could you help me with a potential root cause.? Probably not your pump basket being full causing this but improper air flow caused by debris/dust. I have an sp3400vsp pump. The pool is only 15 months old and I have not had any problems since getting it installed May 2017, other than a small water leak coming from the non suction side of the pump. To view these documents, you will need to download the free Acrobat Reader, which gives you instant access to PDF files. If communication between the ignition board and the display board is not established within 3 s of power-up an error will be displayed. Kept indoors all off season. Any suggestions? The small filter, usually at the wall? Never had an issue with the other motors we have had. Recently when power came on it hums and shuts down after 6 seconds. The Hayward Aqua Plus Automation System should have the capability to accommodate several T-Cell sizes. If the breaker is GFI, those are very sensitive, could be a bad breaker too. Hi, is there a GFI on the outlet? If the salt cell is clean but the salt reading is off, the Aqua Rite will need to be recalibrated. Hi David, impellers that have signs of wear are usually operating without a problem. I just had a power surge in my area and the heater has been turning on and wont turn off. This new one when turned on seems to start, and pump, but the breaker shuts off in probably less than a second. and check each motor lead to ground. Check the shaft, to see that it is spinning freely, then check the wiring to be sure no bare wires are touching bare metal, or each other, or is corroded, and that all wiring is tight and clean. One of the tads were not in the slot. I shut it down again before the problem got worse. Another oddity is both failure are upon Spring re-opening,and the pumps ran flawlessly throughout each summer? }
. (I just bought the house and am new to pool upkeep.). Hi, my name is Javier thoughts? I first thought it might be the motor capacitor, new cap, problem still the same. Dont know if I need a new pump or what. regardless, i am replacing the electrical cord. Any ideas? I heard like a crank sound, as if somethings stuck between a propeller if there is. If so, you can replace just the motor, or the entire pump. It could also be a loose switch in the back of the motor. External bypass is out of adjustment. I opened the control panel during a rain storm (down pour) to turn off the filter. I have a Hayward pro series filter and Hayward pump. Check the wiring. "@type": "Organization",
Hayward Aqua Rite Error Code Guide - INYOPools.com - DIY Resources If not those, it could also be a short in the motor windings, which would be a major failure, requiring a new motor. Its a good piece of troubleshooting. I had my Hayward pool/spa installed about 4 years ago. The pump is only one year old. You dont have a saltwater pool do you? Motor may still be good. Here is the manual: Now, it could also be rust inside the motor, natural when a pump sits for long periods of time, in a non-climate controlled location. Motor again started humming and had to repeat the above steps each time I moved to backwash. Meaning that your control (circuit board) may be damaged, or perhaps the cable is damaged or not connected fully. I may have purchased a defective pump?? After running the pool for a few hours we realized the pump was leaking and EXTREMELY HOT. If your motor is overheating, and shutting off (from the thermal overload switch, located in the back, at 12 oclock), then you have some motor issues, maybe blocked air vents, broken internal fan, or a short across the windings. Pressing on/off buttom followed only by click sound of switch. I purchased a SP1580X15 Hayward pump July 2016 and began using it this year 2017. Some times it has overheated, it did re start, but I want to make sure that the motor is supposed to run continuously. Step 2: Verify that you have enough straight pipe before where you have installed your flow switch. I just went out there to crank them up, after 10 minutes they shut off. ? Everything seems to be set up correctly on the filter and motor. Im still getting air? Air can also enter through split vac hoses, but since yours is new Third problem could be if the new pump moves much more water than the old pump (not all horsepower pumps are the same 2 different pumps of the same hp, can produce vastly different flow rates. Hi Davy, my pump is on a timer and will occasionally fail to turn on in the morning. 6. inspect conduit and wires going from timer to pump, look for water in the conduit, or broken conduit, or rodent damage to wires. BBC News - Dear This Week: your views on our show Hi I have a variable speed ecostar and am now having the drive error, drive stalled. Check the shaft for free spinning movement, and check the capacitor for signs of failure (bulges, cracks, smoke). When the valve is positioned on the filter, it should slide over the standpipe tube, or the center pipe that is connected to the laterals will slide up into the bottom of the valve, and the valve is pushed down to make a tight fit against the filter flange, and then the clamp is supposed to hold it tightly. Hi Joe, the Perflex DE filter has a few dozen flex tubes covered in a mesh fabric. Davy, after going back into the pump again, i have come to the conclusion that the bearings are going out in the motor. I believe you must have some type of switch, for code cant just wire it directly to the breaker. Is the GFCI test button tripped? All pipes are 1.5 and solidly installed with primer and high quality glue for the PVC used. In most cases, its going to be #1, just a frozen motor as we say If the shaft spins freely, and it makes a hum or buzz sound for a few seconds before it trips the breaker, probably #4. The control is set for the wrong turbo cell type. Pump lids are often easier to remove when the Filter Air Bleeder is opened, to relieve vacuum pressure. But most plastic impellers are closed nowadays, with non-visible vanes. Still same though nothing being sucked through basket and minor trickle back out into pool. 5. very dirty pool filter, Every time the pump is turned on with the timer it trips the circuit breaker. You can also call Hayward directly for tech support. Pool Heaters have a thermostat, and just like a house heater, they turn themselves on/off to maintain a temperature. If the amps on either reading show zero (0), then you should replace your PC Board. Typically, any dilemmas with your Hayward pool pump are likely related to either electrical or plumbing situations. If thats what is happening, then the cause of the overheating could be incorrect voltage or fluctuating voltage, incorrect wire size (from breaker or timer to motor), faulty wiring between some of the switches in the rear of the motor, or bad shaft bearings, or poor airflow or blocked air vents, or in some cases, very poor water flow. Get Mountainside Fitness reviews, ratings, business hours, phone numbers, and directions. Ive checked the voltage coming in before the breaker and after the breaker, (at the motherboard location), replaced the breaker just to be safe, but still, overheats. 4. Hi Stephen, could be a loose wire, not just the power wires, but other wires inside the back perhaps, or loose wires on the timeclock or breaker. Check that the motor wiring matches input voltage, if the motor can be wired 110/220V. Tripping the breaker, could possibly be a bad breaker, allowing too much voltage to pass thru to the pump. Have a Hayward pump. While holding the shaft and trying to remove the impeller there was a part that broke off the shaft on the electrical end and I dont know what the part is and cant find it to order it. Hi John, do you mean the filter top pops off? To Become a Customer please Click Here > Skip to the end of the images gallery Skip to the beginning of the images gallery HAYWARD SALT CHLORINATOR SYSTEM 35K - BLUE ESSENCE-35 Sku: BLUE ESSENCE-35 Be the first to review this product If that doesnt solve the problem, then work through the steps below. Poseer una casa es la piedra angular de la riqueza tanto la riqueza financiera como la seguridad emocional. Lots of things to check, but its either air entering the system, or an obstruction, both on the suction side of the pump, or before the impeller. Shaft seals may blow out if a valve after the pump is turned or briefly closed while the pump is running. If the clock motor is dead, you can replace just the motor, but most people replace the entire mechanism. Good that you have the waterfall pump, that will help tremendously. The breaker is probably overloaded. If the amps show a reading that isnt within range, then you should replace your Turbo Cell. The pump/motor, is a power flow LX, 1.5 HP, model SP151521BC, & the Sand Filter is the pro series model S210T. Could also be a clog in the pipe. Hola tengo una caldera Hayward H400 PED2 durante el intento de encendido no enciende m caldera despus de 5 intentos me pone lF en la pantalla. Just push the red button back in. Pump cavitation produces a lower pitched gravely sound, caused by the pump being starved for water from closed valves or clogged lines or clogged impeller. Like it is getting through the shaft seal but the seal is brand new.. any thoughts? Thanks. Hi Brian, is this a DE filter? Hi Nancy, Heat Sinks are designed to absorb the heat from the motor, and dissipate it safely. Valves were replaced with pipe and silicone applied to gaskets and O-rings during install and again yesterday while I was checking this list. 4. remove rear motor cover, loosen screw that holds capacitor (9 oclock) and move it out of the way, so you can fit a 7/16 wrench on the rear of the motor shaft, behind the centrifugal switch. However it is not generating enough chlorine and we are adding chlorine more than we should. Oftentimes I reassemble the pump only to find the diffuser laying on the ground (doh!). We have a Hayward Swimpro Lx 1.0 hp and have a slow leak coming from underneath, maybe in between the housing and the motor. If the salt cell is clean but the salt reading is off, the Aqua Rite will need to be recalibrated. All Rights Reserved. Is that a result of all the water that got in the equipment during the storm? Maintenance. The pump is 18 yrs. We are trying to switch the jumper or selector plug (not sure what its called) from 230 to 115 but the jumper doesnt seem to fit smoothly on the 115 setting the prongs it has to slide over seem too far apart and Im afraid of breaking it. Inspect the circuit board, blow off with some air, and look closely at the 3 wires for any insects, spiderwebs or corrosion of any type. Chapter 1: The Evil Emperor's Son. Hi Steven, probably the breaker tripped or the GFCI test button popped out due to some water touching some wire. Do we need a new pump or can the electrical cord be replaced? Hi Mike, its hard to say not knowing which control system you use. The 1.5 hp pump was so strong you couldnt stand in front of the single return, which is why I used smaller pump. If power is reaching the box, getting past the transformer, and the fuse is good, it sounds like the main PCB is the issue. Hi Chad, when a motor makes no noise at all, I suspect power issues. Although in low speed, chlorine is not generated so not sure why even run the low speed. There may also be air leaks on your pump, particularly the pipe or valve that is threaded into the pump, must be sealed with thread sealant tightly. Read up on it and seems it happens a lot and the motor drive needs to be replaced. The unit works fine for approximately 4- 6 hours, then the Check Salt and Inspect Cell flashes (salt level on the unit reads 2600 ppm). 8. check power at the motor, with a multimeter set on 240V+ place test probes on the brass screws or terminals where the two power wires connect. Hi Mark, hard to say if it does not display any error code, the caution symbol on a Hayward Heater is usually accompanied by an error code, LO being the most common, for low water flow. Thinking of switching to PentAir, I hear they are better built. Any idea why this might be happening? Sounds like a leak from the shaft seal, although it could be dripping from the pipe carrying water out of the pump, running down and dripping off the bottom. Step 2: Did you properly install your switch? Its a Hayward pump. Holding the shaft stationary (so it wont turn), unthread the impeller, counter clockwise, to remove. Thought he motor was defective. Interesting enough, if I place it in super chlorinate mode, it will produce chorine. A longstanding legal battle over control of the old Apex Department Store properties in Pawtucket appears to be headed.. Apex Legal Funding is a lawsuit financing company that provides pre settlement funding and post settlement funding to plaintiffs. "identifier": ""
http://www.inyopools.com/blogSHOP at our online store! "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
2) loose pipe coming into the pump (no sealant, or overheated and slightly shrunk), 3) Loose valve lids or o-rings, air-leaky valves in front of the pump (main drain, skimmer). Hi Tom, there is an o-ring that seals up the tank flange to the valve flange, its usually on the valve, when you remove the valve, might need replacement and/or a good cleaning and lubing. On Jandy valves, the spurt may be from the lid, or from the center of the lid around the stem, from a broken or missing grease cap (grey valves), or from a crack/damage. If you see an increase in pump pressure, ensure that there is no blockage preventing the flow. Humming noise is usually associated with a bad capacitor, a black cylinder at 9 oclock in the rear of the motor. Just replaced my old Polaris booster pump, 3/4 hp, with a 1hp pump. I noticed the pump wasnt running this week and saw the LED display was off and had moisture in it. When I turned off the pump I saw that it spit a little bit of water out of a Jandy Valve. This year, I have replaced all the plumbing from the pump to the filer. In this Pool Care Basics Video, we discuss how to clean a salt cell. If it continues, a new o-ring might be the ticket, yes. Something about level of placement of pump in relation to the water surface. Guess I was wrong. Air could also be entering the pump from the threaded pipe or union that is attached to the inlet port, which may also spray or drip when the pump shuts off. Any ideas or what else to check? Does the panel just need to dry or did I cause possible damage? If very clogged, you can usually tell, because debris will float out and you can grab some of it with your fingertips or with pliers. The pilot lights, but when I try to jump test the gas valve it clicks and snuffs out the pilot light. HAYWARD SALT CHLORINATOR SYSTEM 35K - BLUE ESSENCE-35 - MT Pool Distributor Mine hums and then trips the breaker. Pool360 - Blue-essence-20 20k Gal Salt Chlorination System - Poolcorp Hi Bobby, so you have power at the motor, but no noise. easier. Occasionally, while running, it trips the breaker. "thumbnailUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
I need some advice for my 15 x 30 x 48 AG oblong swimming pool. I dont want to over tighten it. Inspect the motor shaft for any obstructions. Again, flow rate is good but it doesnt make the change in pressure like it should when switching to sweeper. Most above ground pool pumps are not self-priming, and mot inground pumps are self-priming. I have opened a pool and I have kept pump running 24 hrs due to Alge but few hours later there is no water moving in pool. I disconnected it and plugged the Aquatrol in alone; that worked fine. My hayward powerflo matrix 1.5hp pump doesnt turn on after working fine the whole month of June. Hi Jim, bummer! you can keep running it, while you get parts sure. of and in " a to was is ) ( for as on by he with 's that at from his it an were are which this also be has or : had first one their its new after but who not they have LibriVox is a hope, an experiment, and a question: can the net harness a bunch of volunteers to help bring books in the Dec 14, 2021. This is actually the second motor in 6 months. I have it on a 15 amp breaker with a few other items, the motor after running is very hot to the touch. have the pump motor rebuilt by replacing the bearings and shaft seal, or having an electric motor repair shop do it for you, or 2) replace the motor with an exact replacement motor + new shaft seal, or 3). I have a 2 year old Hayward Pump 1 HP wired for 110 with 20 Amp breaker. 3 No air bubbles on my returns when not vacuuming So it seems its changing speeds from slow to normal or is shutting off and immediately turning back on. If your previous pump was also 230V, as it likely was Im not sure what could be the problem, probably not a bad pump, but maybe some wire is disconnected, from the terminal board to the capacitor, for example, or otherwise mis-wired, internally perhaps? For slide valves (aka push-pull valves), an o-ring on the bottom plunger disk has gone missing or is worn, torn or badly deteriorated. I have a t-15 cell. If it makes no noise at all, that is often a loose wire or no power. The pipe from the pump is connected to the valve in the port labeled PUMP and the pipe returning to the pool connects to the port labeled RETURN. Looking for pool parts? Still the same results. "@type": "Person",
As to the filter, pool filters need to be matched to the flow rate of the pump. Is it a defective motor or something else? You must log in or register to reply here. If not, use an outlet tester or plug in a different appliance (light, hair dryer, fan) to see if the outlet has power. Our pump is going through this one-off cycle similar to what others are describing. Is that a reason to replace impeller? Hmmm, not too sure about this question Jay, there must be some explanation. I swapped the pump assembly with an almost identical Hayward that I found in the garage (bonus!) We just has this pool installed year, and brought the motor inside the house. (This pump is on a regular 20 amp circuit breaker, not a GFCI.). "@type": "Person",
This is common maintenance for any pool Troubleshooting Your Hayward Aqua Rite System, Copyright 2020 INYOpools All rights reserved. I have a Hayward Super II pump. This is weird, no? "height": "219",
On initial trial for ignition. If the filter multiport was recently re plumbed, be sure that the pipe from the pump goes into the valve port labeled PUMP, and the pipe to the pool is connected to the valve port labeled RETURN. So I messed with the wires a little and I got it to turn back on. I would start by lubing the pump lid o-ring with pool lube, and trying to tighten the lid a bit more if you can. The stationary switch copper tabs may be bent, or may have a wire crossing between them, have a loose screw or have some other issue that prevents it from opening, and releasing the capacitor. Better call an electrician for that though, 2 speed Hayward pool pump motor is very loud only when on high speed. This just started. Wouldnt turn back on for a while even after manually flipping the switch. Was running fine. Remove and replace the two seal halves, in the same orientation as removed, spring half slides over impeller stem, donut half is pushed into seal plate. I removed it from the pump housing to troubleshoot it was pumping weakly before stopping. Does the capacitor look bulged, cracked or leaking? HI Mike, the seal and the motor may be separate issues or they may be related. Thank you for the quick response. pool water analysis near me; camel leather reclining sectional; chiaogoo twist shorties set; 24 emsco resin hydro pickers garden system; pool cover 16x10 oval; Is there a reset switch on the pump? Then back to no pressure. When this has been corrected, shut the power down to the pump and rest it after 15 minutes. Has worked fine until today. Hi James, I would think that could be one of the E-clips used on the bump shaft may have broken off, or an o-ring has slipped off. Hi John, the cap for that motor is START CAPACITOR, 161-193 MFD (BC-161) we dont carry it, but easily found online. If it is on low it works properly. HAYWARD SALT CHLORINATOR SYSTEM 35K - BLUE ESSENCE-35 This is wholesale site for our registered customers. If not that, it could be a loose wire connection. Frayed wiring inside the plug or socket. "width": "611",
Inherited an old Hayward super pump that hums but doesnt turn over, checked the shaft which moves smoothly and replaced the starter capacitor to no avail. Hi Didnt I switched it off properly? Hi Ryan, it possibly could be a problem with running two extension cords, also could be voltage fluctuation, or loose terminal connections, or just a pump going bad. Then check the GFCI for loose wires. replace the entire pump with exact replacement. The pump starts up fine and draws water but then it starts clicking as if its shutting off and on. Copyright 2022 In The Swim. (PUMP and RETURN pipes). I dont want to assume but I am guessing the pump was just going bad, thus leaking voltage in the pool. A very thin layer of rust develops between the stator and the rotor inside the motor, and getting a 7/16 open end wrench on the end of the shaft, and working it back and forth, breaks the rust and frees up the shaft to spin. Please consider. What am I doing wrong??? Hi Chuong, the Leslies RS750CA is the same as the Hayward Super II pump, which are $500-$600. 220v. Rust can develop inside the motor that you can break free, by spinning the shaft a few times. hayward blue essence troubleshooting - Lyriclifeclothing.com It could be air in the pump, or it could be that the pump is too big (powerful) for the number of pipes. Just bought a brand-new Hayward pump , starts up in primes great but in about five minutes there was no suction or water flow back to the pool . I have a maxi-flo 2 and it just stopped working. After connecting the device, the flow led flashes for one minute and turns off. If the shaft is free turning but it makes a hum or buzz sound, usually followed by a tripping breaker, check the capacitor, it may have failed. If pressure is lower than normal check for air leak on the suction side of the pump, or a clogged impeller, or low water level, stuck skimmer weir, or closed suction valves. I was just wondering if you thought that could be the issue unless it could be something else. 1. drain plug Another possibility could be a clogged pump impeller, should have mentioned that earlier. It had a non Hayward motor installed before. Home / Pool Equipment / Pool Heaters & Heat Pumps / Hayward Pool Heater Troubleshooting. Since you didnt say it trips a breaker, its probably not a short or ground-out of power, although it still could be, typically a wire touching metal other than the terminals on both end of the wire. Thanks. This spray is not usually noticed, unless the pump has been running nearly full-head or full-speed. I checked the pump and is is very hot. Whats that part called in case I do break it? If voltage is normal, there may be a loose wire in the motor, perhaps behind the terminal board, or a bent wire that is touching some metal housing, or bent and touching another wire. Just purchased a Hayward SP32002VSP. Can I replace a specific part or do I have to buy a new one? It did never tripped during program. the pop may have been the capacitor blowing, its a black cylinder located at 9 oclock in the rear of the motor. Next, check continuity from lead to lead. If this is an ABG pool, check the skimmer hose and adapter fittings. Any idea what could be causing this issue. Check power at the switch or timer in the same way as the motor, at the other end of the wires running between the switch/timer and motor. My pump, when in the normal running position, leaks water in a slow steady flow out the tubing used for backwashing. Did I mention low water level, stuck skimmer weirs, or clogged skimmer baskets? {Thinking it could be the timer motor) Problem still the same. Or maybe the glue that Im assuming is no longer working? I replaced the start capacitor as that sounded like that was the most likely culprit based on everything I read, but noise still persisted. Hayward Aquarite T-CELL-5 | 20,000G Replacement Cell - Salt Pool Store main drain and skimmer) to feed this thirsty pump. If thats not the issue, is the pump sized correctly for the filter, and not under/over sized? I like to use a Drain King on pumps that have priming problems, to get them started, get the 2 model at any hardware store. My pool suppoier said 50lb but the info on the description of the filter on the site where purchased says 100 lbs. BLUE-ESSENCE-20 20K GAL SALT CHLORINATION SYSTEM (HAY-45-0020) Product # : HAY-45-0020 Mfg : HAYWARD POOL PRODUCTS INC Mfg # : BLUE-ESSENCE-20 (FLORIDA ONLY) Department : FEEDERS | CHLORINATORS | SANTIZERS Product Line : Salt Generators UOM ( Default ) : EA Obsolete : This product is not obsolete.