Wood burners consume combustion air in response to the amount of chimney draft produced by the heat of their own flue gases. Thanks. On the other hand I wonder why on the diagram there are two potentiometers, but in your explanations you only quote one, can you tell me a little more about the second.cordially. Would you be open to this? 24 Ga Cast Iron 4.44.4 out of 5 stars(245)
Fireplaces and Wood Stoves Have Proper Ventilation - PNNL Depending on your model of wood burning -I didn't even have to cut an opening to the outside. CleverAir is an automatic air damper that adjusts the air supply to the stove automatically. Now there are . Writing to let you know we are very happy with the #2500. WARNING : always let a minium drawing. The pressure inside the house will still be affected by wind to some extent, but the flow resistance offered by the envelope tends to remove the peaks and valleys of high and low pressure caused by wind gusts. To many coals makes it run hotter and run the risk of a chimney fire. Thank you in advance! Not inside the chimney !! FlexBurn Technology. Sign up for our Newsletter to receive updates & promos. This last factor makes the biggest difference in making this kind of system more efficient. and efficiently. In the fire in your wood burning stove is This site uses cookies to offer you a better browsing experience. A little experimentation and properly seasoned wood helps keep you warm and lowers your heating bills. When servicing systems with direct outdoor combustion air ducts, look for soot or staining inside the duct. producing a lot more smoke as a result. Reply Freedom Bay 1995-2017. every piece of wood. "I am entering the second heating season with my wood-burning boiler and could not be happier.I am heating over 3300 square feet and will add a hobby green house to the system this year. Model: 8013. If, on the other hand, the passive inlet is located above the house neutral pressure plane, air will flow out. Buy Now. Understanding how best to use the vents on your wood burning stove to control a fire is a learning process. Kindling lights easily and burns quickly, but it does not sustain a fire for long. To secure optimal and eco-friendly combustion in your wood burning stove, your wood burning stoves air supplymust be regulated very precisely every few minutes and every time youput firewood in the wood burning stove. on Step 1. u didnt know this but if u put a small chunk of live ember into that amethyst. Patent number: 4424799. A fire requires Read more: Awair element indoor air quality monitor aqm8002a.
Better burning wood stove with a external air intake! - YouTube When you've scrubbed the inside, vacuum out any ash and soot from around the base of the stove. The 2000 works great (Im glad I purchased it). If you do not have an outside supply, it will pull it from inside the house which will depressurize the house and the fire will burn poorly. It may not display this or other websites correctly. It is highly recommended to test the system before deploying it .. Buy Now. In manual mode the air distribution can be controlled in each combustion phase-even in the event of a power outage. How do I control the airflow in my wood stove? Step 1 It is important to ensure that all of the stove's vents are open before kindling a fire. Lopi LX 1982-1987.
DWARF Direct-Air Intake Box - Tiny Wood Stove As a person who grew up without fires, and is currently in a house with a wood fire this article has helped me to figure out what I needed to do thank you, Great article, really easy to follow and understand. Wondering if you have any objections for doing it this way. In a tight house, the lower infiltration rate can interfere with the chimney draft, making it tough to get a good fire going. Calibrate the zero angle of the servo motor. Secondary air tubes . help you have hotter and longer fires, while also helping to reduce the amount Damper vents work like large bolts with a flat side that closes over the holes. Your comment are right on. We have been heating 4 buildings this winter with the new boiler. Over 400 old and current manufacturers, with unique parts and patterns. Simply, easily and automatically. per cubic foot.
wood stove automatic air intake control How to Adjust Wood Stove Vents | Home Guides | SF Gate We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. But I have friend that owns a tree service and he dumped a huge dump truck of oak and pecan on the back of my lot so the wood is practically free. The air valve control housing bolts to the air intake the wood stove. For me I watch the coals, keeping them under control controls the heat. Simply, easily and automatically. Certain wood stoves might not have to have a fresh air intake specifically connected to outside the house, since it can get enough air from inside the house. The orange arrow points to the woodstove air inlet draft control. ]I do not use the buzzer for refill so i just didn't install it and left the code the same.The problem i have is the end of fore is too soon. Much of what is going up the chimney is exhaust from the wood itself but the fire needs to pull oxygen from somewhere. I think that this would go a long way towards a remedy. In the 1980s, when large exhaust systems like downdraft kitchen range exhausts began to cause spillage from fireplaces and stoves in reasonably tight houses, a consensus quickly formed around the idea of bringing combustion air from outdoors, just as had been done in mobile homes for decades. L'ensemble est mont, mais je n'arrive pas avec le codage du programme, en fait l'cran lcd s'allume mais aucune indication sur celui-ci. It's important to light a fire in your wood burning stove correctly. air to the different components of your stove, which will help you understand If the fire is burning too quickly, simply On the other hand if the vents are too far What is the air intake on a wood stove called? Fix the valve on the hook, I drill three small holes and put super glue inside. 24 Volt Damper Control Box $ 377.00 USD Since 1972 originally known as National Stove Works Our goal many years ago was to create an indoor wood burning furnace and indoor wood burning boiler that heats quicker, is energy efficient and will provide you with minimal costs throughout the year with wood and repairs. Above is a beautiful Jotul woodstove that I (DF) traded to Paul Galow for a fancy wristwatch. air vent that is located underneath the stove, while there are also air vents close down the air vent as the fire progresses without causing the fire to Larger sized logs are harder to catch To control a wood burning stove: Before lighting a fire, ensure that all of the controllable air vents on the stove are open.
How To Use The Vents To Control A Wood Burning Stove - Fireplace Universe Building codes in various jurisdictions in North America require that fireplaces, and in some cases wood stoves, be provided with a source of combustion air from outdoors. But the result is quite different : 1) Incoming fresh air is quite warm, and this heats the room as well ;2) the room is slightly over pressured by this incoming hot air forced in by the fan and this prevents small cracks in doors, around windows, small holes letting fresh but COLD air seep in. Hello, you can indeed reset the "Fire End" message by turning the potentiometer to zero then 100% again. Amazon's Choicefor wood stove damper COLIBROX Manufacturing Group BM0051-A Cast Iron Stove Pipe Damper, Black 4.64.6 out of 5 stars(213) $14.59$14.59 FREE delivery Sat, Mar 4 on $25 of items shipped by Amazon Or fastest delivery Thu, Mar 2 Simpson Duravent Stove Pipe Damper 6" Dia. It is sometimes assumed that taking air from outside through a duct saves energy because the stove doesnt use up indoor air and cause outdoor air to be drawn in through leaks to replace it. Our next project will be installing the domestic hot water coils in the spring.". If the weatherhood of a passive inlet is on the windward side of a building, wind pressure is likely to force air into the building; if the weatherhood is on the downwind side, the negative pressure zone created by the wind is likely to draw air out of the house, possibly depressurizing it. Just installed a Blaze King Ultra and it HAS a thermostat, and it works really really well. 1 year ago. The kennel buildings have never been so warm. Perfection would be an air supply provided at neutral pressure and with no resistance to flow. how to best control a fire in you stove. There may be circumstances in which a direct outdoor air supply is considered necessary. Capture and send the heat up to 10 metres across the room by using this high-speed, compact mini-turbo Wood Stove Fan. More if you consider that hot air takes up more space than room temperature air.
Automatic damper: CleverAir - Eksklusiv kvalitet - RAIS Wind effects around the house also affect the direction and volume of flow through a passive inlet. Osburn 5 Inch Diameter Fresh Air Intake . In other words, there is no simple way to provide the large volume of air used by a fireplace by supplying it from outdoors, except perhaps by opening a window.
Wood Stove Fan - Solazone Australia By using our website, you accept the use of cookies. It is useful to keep in mind a key physical principle: AIR FLOWS TO ZONES OF LOWER PRESSURE through any available opening.
How to Use a Wood Stove Damper | Hunker Closing When you're using the wood stove on a regular basis, clean inside the firebox once a week. If you find that you're having it fire too hot (above target temperature), you should probably change kP to something lower than 5 (5 was the default value). But I can't find the values of the used potentiometers. So the outtake lets in FRESH WARM AIR. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. $14.99. The STL files are available for download. This lever controls the position of an air valve internal to the air control housing and controls the volume. Swing Wood Stove Fan circulates heat more widely Solazone Swing Wood Stove Fan This new model has the widest air circulation, as it oscillates whilst it works. The average air consumption of a modern wood heater is in the range of 10 25 cfm, which is very small compared to the natural leakage rate of houses. DETAILS IN SHIPPING POLICY Wood Stoves Price $0-$999 $1000-$1499 $1500-$1999 $2000 and + Size Small Medium Large Extra Large Certified for installation Mobile home Alcove EPA 2020 Heating area 0 ft4000 ft HOW TO DETERMINE MY HEATING AREA? Not providing enough air supply to stove is dangerous. I have thought about putting fins on the flue. . Anotherdisadvantage of using the temperature method is that the automatic control device will open up for air in the final phase of combustion. Add to Cart. on Introduction. Outdoor air supplies connected directly to the stove or fireplace combustion chamber may seem like a good idea and it was once believed that a direct supply would isolate the combustion appliance from room pressure variations.
Wood Stove Draft Adjustment & Control - InspectAPedia When it came to the question of how often people regulate the air supply during the combustion process, it was clear that few people do it often enough when they do it manually: Thats why its a very good idea to invest in a wood burning stove which regulates the primary air inlet controlautomatically. They serve as a small thermal mass that slowly releases heat into the room after the fire has gone out. ---The chemical reaction of the burning releases far more heat than what's required to heat the air an extra 30-60 degreesF which is relatively trivial. It will take a little while to find the right setting on the damper not to open not to closed. I'll come edit this if I adjust anything.Also, to everybody implementing this, USE AN UNGROUNDED THERMOCOUPLE. Wyld Bill Feb 12, 2011 Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment. Continue with Recommended Cookies. -This is 6" flexible foil dryer vent hose that you can get at most any home improvement store. Two forms of outdoor air supply have been used: passive make-up type air supplies and direct-to-combustion chamber air supplies. Do you have any updates.
ASDP automatic air supply controller for freestanding stoves Its a big advantage to choose a wood burning stove wih an automatic control device. If you haven't already created a layer of ash at the bottom of your stove's burn box. The worst-case indoor air pressure environment can be measured using the house pressure test procedure, and can be controlled either by limiting exhaust flows or by installing a powered make-up air system. Going to bed. The fire burns through the wood more quickly as 7 years ago. New air twist air inlet damper for wood burning stove fireplace freestanding . But as far as stopping cold drafts which might cause many people to use wood I don't see an efficiency gain from a mechanical perspective. If your local building code forces you to install outdoor air, you will have no choice, but be aware that it will not reliably improve the performance of your wood burning appliance or result in higher efficiency of the system. Read more, Wood burning stoves are an eco-friendly source of heating, Eco-friendly combustion with correct air supply, Efficiency - make the most of your firewood, Place dry firewood in the fire boxof your wood burning stove, Enjoy the heat and the sight of the flames the next couple of hours, Pull the wood burning stoves primary air control inlet handleas far out as possible and use the Aduro-key to keep it from closing, Youll use less firewood. wood stove automatic air intake control. And remember to make sure your firebox is well-shoveled so you wont have to worry about ashes falling back down into the hearth! I built an automatic regulator that do it for you. However, when their doors are closed, wood heating appliances exhaust comparatively little air from the dwelling. Perfect sealing is not a realistic goal because it would be difficult to achieve at the time of construction or installation and is unlikely to be permanent. Ive explained in more detail below how we 11 years ago Behind the chunk of granite is a pile of aluminum ingots from my backyard foundry. It can produce fatal CO gaz or incomplete burned gaz explosion. The GermanTechnologie- und Frderzentrum made a survey as a part of the project called beReal of how wood burning stove owners really fire in their wood burning stoves. Potentiometer are 10k you can find in most Arduino kits. Once the kindling has become fully engulfed in flames, begin to close the controllable vents. This way you will get the most out of the firewood, save money on heating your home and you're guaranteed eco-friendly combustion. how fast the fire burns through the wood and the total heat output. but closed down enough so that enough air is being supplied to the fire to keep Adding larger sized pieces Precise and correct air supplyensures optimal and eco-friendly combustion, Better indoor climate because combustion takes an even course. With the patented Aduro-tronic automatic control, the primary air supply is automatically regulated, so you do not have to regulate the combustion. going.
Share it with us! Add to Cart. IntelliFire Touch Controls. the vent. This mostly takes the form of a four inch diameter hole in an outside wall with a duct attached running to the stove or fireplace, connected either directly to the firebox or to a location where it can be heated by the fire before entering the room. I've set kP = 7.5, kI = 0.01, and kD = 0.00005 to help with this. In cold weather, when temperature difference produces a pressure difference due to stack effect, if a passive make-up air supply is located below the neutral pressure plane of the house (and there is no wind effect and no exhaust systems are operating), air will flow into the house. After viewing product detail pages, look here to find an easy way to navigate back to pages you are interested in. The air wash system helps to keep the glass door clear on our wood burning stove, and you can find out more about air wash on stoves in another one of our articles here. Before lighting a fire in a wood stove, I found that with the target at 130C, the default configuration would end up keeping my stove at 118-124C instead, so errI (integral) would keep accumulating, thereby causing it to enter "Fire End" mode after approximately 30 minutes every time I used it. If the chimney wins the competition, the flow direction is up (successful venting); if the fan causing the depressurization wins, the flow is down (spillage or backdrafting). SBI 1/2 Inch Black Coiled Stove Handle; Empire Automatic Blower for Heritage Cast Iron Gas Stoves - CIB-3 .
CA2692384A1 - Variable combustion air control for wood stove - Google Im currently, still using a Thermo-Control Ultimate Wood Burning System Model 400, purchased October 1979. Once, a wood-burning stove was black, but once a refrigerator, of course, was white too. or Best Offer . it going quickly and get the stove up to operating temperature.
Company . Any way you could help me add a variable where if the temperature drop below let's say 124C, it would open the vent 100%, while keeping the refill and end of fire cycle?
Arduino Wood Stove Controller | Hackaday.io Imperial Bm0242 Cast Iron Damper, 4" Dia. Woodstoves also regulate the wood fire and thus stove temperature by adjusting the combustion air intake to the woodstove at the fire door. The stove automatically regulates the air supply to ensure that it is optimal at all times.
Wood Stove Accessories: Huge Selection + Reviews (Real) - EFireplaceStore Share it with us! . A single lever air control lets you control the fire. The aim at the start of any fire is to get If the air supplyis controlled by the temperature of the smoke, the advantage is that you wont have to take differences in chimneys into consideration. and you'll be doing the environment a favour. In general, therefore, wood stoves and fireplaces that are vented by natural chimney draft should draw the air for combustion from the room in which they are located.
Our Harman Fireplace Wood Stove goes BOOM! - WoodchuckCanuck.com $10.00 shipping. Thank you, Robert Fusco, Alpine, CA. You get a notification when a wood refill is needed. Ashley Hearth Products 3200 Wood Stove. Modern. on Introduction. very smart. 3. produced. The problem is that the after gases do not burn off properly as this little video shows. The 2000 works great (Im glad I purchased it). Never did anything with Arduino or any programming but willing to try. There is also a row of small air vents If an exhaust fan like a kitchen range hood depressurizes the room to a level greater than the draft produced in the chimney, combustion gases will leak from any available opening, such as gaps in gaskets and the joints between factory-built chimney sections (illustration right). As an example, the average weight of air is 0.0807 lbs. I was disapointed to find that the VC Defiant I just bought is NOT a thermostatic control but just a manual air shutter adjustment. Starter LS. Yes, a lot.
High Efficiency Wood Stove | HT-3000 | Drolet Since the air consumption of a wood stove is so low, the risk of reversal of a ducted combustion air supply outweighs any advantage gained by bringing air from outdoors. 'Nuff said. You can get some nice PID curves by getting the values with Arduino serial port and plotting them. When the temperature goes up the desired temperature (consigneTemperature in the sketch) the valve should close.
Fresh Air Intake for a Woodstove or Wood Heater W/ Round Intake However, two key findings from the research into outdoor air supplies serve as cautions against the widespread use of direct combustion air supplies. Rectangle . 4 years ago. The consent submitted will only be used for data processing originating from this website. The automatic control device willregulate the air supplyin the wood burning stove, and the regulation is based on either time, temperature or oxygen. Just a bit of labor to cut it up and split it. The advantage of taking combustion air directly from the room in which the stove or fireplace is installed is that the building envelope moderates the effect of wind on the air supply by damping out wind-induced pressure fluctuations. Heritage. The disadvantage is that the system was made for a normal chimney. To restart the system, put the potentiometer to zero then to maximum value. There was a thread on this a few months back, the Blaze Kings do but I think there was another stove that had one also. Direct air supplies can reverse flow direction if the weatherhood is exposed to a negative pressure in excess of chimney draft (illustration below). ACC feeds the fire with air when it's needed mostand controls it for consistent, extended burns. One third of an air change in a 1500 square foot house is 4000 cubic feet, or 66 cfm. Read more about why firing with firewood is carbon neutral. It can produce fatal CO gaz or incomplete burned gaz explosion.Disclaimer : I am not responsible of any use of this project. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Hi, Im James, Ive been using traditional open fireplaces and wood burning stoves for many years, and Ive also recently bought a bioethanol fireplace. Is it to prone to problems? Connect the thermocouple to that wire and fix the end in contact with the non isolated part of you stainless steel chimney or in contact with external part of the stove. The case of the valve and servo is 3D printed. The advantage of this simple system is that it doesnt rely on electricity and that the automatic control device is placed outside of the fire box. 13 years ago ft. EPA Certified Wood Stove with Stainless Steel Ash Lip and Blower (23) $1,559 00 / each It was very easy to install. In order to get the most out of a wood burning stove without an automatic control device, it is important to know a lot about the combustion process. This was really clear and in depth. However, getting the most out of your new stove is a learning curve.
Quick Answer: How Does Air Enter Lopi Endeavor Wood Stove If you havent already created a layer of ash at the bottom of your stoves burn box. A regulation need some configuration, you may have to change the default parameters : float temperatureMin = 50; // under this temperature, the regulation starts an integral measure to estimate end or fire and close the valve, float consigneTemperature=120.0; // the desired temperature measured by the thermocouple, float kP=5; // P parameter of the PID regulation, float kI=0.0005; // I parameter of the PID regulation, float kD=0.00005; // D parameter of the PID regulation, float refillTrigger = 5000; // refillTrigger used to notify need of a wood refill, float closeTrigger = 15000; // closeTrigger used to close vlave at end of combustion and notifiy end of fire, float potentioMax = 1023.0; // Potentiometre calibration, int potentionRelMax = 80; // Potentiometre value above which the regulator runs in automatic mode. A stove or fireplace will be fussy to start and likely to spill when it tries to get its combustion air from a seriously depressurized building. Each type has its advantages and its disadvantages. You can also add a stack robber on the flue pipe- this helps capture lost heat. A Pocket Sundial From a Broken Pocket Watch! But direct combustion air supplies cannot effectively be connected to a fireplace without doors because insufficient pressure difference is created to drive the flow. ACC technology delivers precision start-up and air control for consistent burns. You don't find what you need or you are not sure? 12 years ago At 800F actuator will be completely extended and close the damper.At 600F actuator will be completely closed but damper will be hundred percent open. level. Our family has an old vacation property in upstate NY that was FREEZING cold during the winter that we stayed there, and it was because of the negative pressure and air leaks that you mentioned. Below,you can read about how the patent-applied for automatic Aduro-tronic works. Or on the case of one I know a shed full of smoke This means less work, less wood use and an improved combustion. Wood stoves require fresh air to burn, because that's how fire works. Drolet 5" Fresh Air Intake Kit For Wood Stove On Pedestal New. Fewer breakdowns. AC01358 3" X 25' INSULATED FLEX PIPE FOR FRESH AIR INTAKE KIT. Winter Weather/Power Outage. Ive explained in more detail how to build and light a fire in a wood burning stove here. The smooth rock on top of the granite block is my bedtime foot warmer on really cold nights. Shop products from small business brands sold in Amazons store. This air has higher oxygen levels than recirculated air from inside the room unless the HVAC system also includes a makeup air system to add air from outdoors. Reply In Indoor Fireplaces, Wood Burning Stoves by James O'KellyJanuary 2, 20208 Comments. This project consists of an Arduino Mega with a thermocouple sensor to measure the stove and room temperatures. Zone Damper 8" Round Professional-Grade (HVAC Zoning) - Preminum replacement for Honeywell, EWC, Durozone, more (08), Chimney 69128 6 Inch Dura-Vent DVL Double-Wall Stove Adaptor With Damper Section, DuraVent 6DBK-ADSL Snap-Lock Adapter with Trim for DuraTech/DuraPlus/DuraLiner Chimney Connections, 6", FIREHIKING Stovepipe Spark Arrestor Chimney Rain Cap for 2.36inch/6cm Stainless Steel Stove Pipe, Vermont Castings Ceramic Fallaway Handle Assembly (White with Nickel Nub) 0004342, JIMBON 6 Blade Small Wood Stove Fan Heat Powered Silent Circulation Fireplace Fan for Wood Burners Stove Log Burner Operation Eco Friendly Efficient Heat Distribution With Thermometer, US Stove DR6 Barometric Draft Regulator, 6-Inch, SoloWilder Stovepipe Spark Arrestor Male-Head Version 2.36 inch Chimney Rain Cap 18.7cm/7.4in, SoloWilder Transposed Stovepipe Female-Female Version 2.36 inch Flue Connector Stainless Steel, Magnetic Wood Stove Thermometer Fire Stove Pipe Thermometer Flue Pipe Temperature Meter for Avoiding Stove Fan Damaged by Overheating (2), Hi Flame Coated Sand Casting Cast Iron Fireplace Ash Dump Door, Midwest Hearth Wood Stove Replacement Gasket for Woodburning Stoves - Graphite Impregnated Fiberglass Gaskets (5/16" x 84" Rope), Moisture Meter For Wood - Pin Type Digital Dampness Moisture Sensor Detector For Wood, Firewood, Brick, Drywall, Paper, Floor, Plaster - User Friendly Accurate Woodworking Moisture Gauge, VODA 4-Blade Heat Powered Stove Fan for Wood / Log Burner/Fireplace increases 80% more warm air than 2 blade fan, GALAFIRE Magnetic Stove Thermometer Oven Temperature Meter for Wood Burning Stoves Gas Stoves Pellet Stove Stoves Avoid Stove Fan Damaged by Overheat, CXhome Heat Powered Stove Fan for Wood, Fast Start, 4-Blade Fireplace Fans, Ultra Quiet, Increases 80% more Warm Air, Energy Saving, Carbon Emission Reduction, Flat Gasket Tape for Stoves and Fireplaces, Self Adhesive Flat Gasket, 5/8"x1/8" Length 72" Wood Stove Flat Gasket Tape, Vermont Castings Black Wooden Handle 1600664, Magnetic Top Thermometer Wood Stove Thermometer Stove Chimney Flue Pipe Thermometer Stove Temperature Meter for Avoiding Overheat (2 Pieces), BBQ Smoker Supply wood stove ajustable grill vent damper 8" inch firebox QTY1 AL .#GG4346 43ETR98-Y530974, Vermont Castings 5004265 Damper Handle Stub, Stanbroil Magnetic Wood Stove Pipe Thermometer, Flue Pipe Temperature Meter for Wood Log Chimney Pipe, Metal Fireplace Damper Pull with Solid Brass Handle, Jamborum Backdraft Damper 4 Inch Round Prevent Unwanted Drafts in Metal Ducts Professional-Grade, Heavy Duty Galvanized Steel with Aluminum Flaps Spring-Loaded, One-Way Airflow Insert, Stanbroil Graphite Impregnated Fiberglass Rope Seal and High Temperature Cement Gasket Kit Replacement for Wood Stoves - 1/2" x 84", TWO PACK 2 BBQ Smoker Supply wood stove ajustable grill vent damper 8 inch Aluminium, Apipi 2 Pcs Wood Stove Gaskets, High-Temperature Resistance, Graphite Impregnated Fiberglass Replacement Gaskets Tape Self-Adhesive for Smokers Woodburning Coal Stoves (11/16" x 3/16" x108" in Total), iPower 6 inch Backdraft Shutter Damper Back Draft Blocker, One-Way Airflow Ducting Insert Backflow Preventer with 2 Inline Springs Loaded Folding Blades, 6", for HVAC Extractor Fan Vent, Range Hoods, Wood Stove Thermometer, Foedo Magnetic Thermometer for Wood Burning Stoves Gas Stoves Pellet Stoves, Helps Monitor Temperature and Avoid Overheating of Stove Fans, Vermont Castings 7001148A Grate for Dutchwest 2462, M&G DuraVent DURAVENT 6DBK-E90 6" DuraBlack 90 Degree Elbow, Black, Wood Stove Thermometer Magnetic, Oven Stove Temperature Stove Top Thermometer for Wood Burning Stoves, Gas Stoves, Pellet Stove, Avoiding Stove Fan Damaged by Overheat, AC Infinity 8 Backdraft Damper, One-Way Airflow Ducting Insert with Spring-Loaded Folding Blades for 8 Ducting in Range Hoods and Bathrooms Fans, Vent Systems 6'' Inch Backdraft Damper - Backflow Shutter - Heavy-Duty Inline Springs Loaded - One-Way Airflow Ducting Insert - Inline Fan Vent Deflector, Fireplace Tools Sets for Your Home by Amagabeli.